BLC relay switch insert HVAC house electronics 2912

EAN
4011334242215
Packaging
1 Piece

Technical properties

Func­tions
  • Func­tion
    switch on delay for HVAC channel can be activ­ated/de­ac­tiv­ated perman­ently with BLC button, when cover is detached, the switch status is retained (wall­paper func­tion)
Main elec­trical features
  • Frequency
    50/60 Hz
Voltage
  • Oper­ating voltage
    230 V AC
Elec­tric current
  • Motor switching current (HLK chan­nel)
    2.1 A
Power
  • Breaking capa­city
    max. 1000 W
  • Switching capa­city, HLK channel
    max. 800 W
  • Conven­tional trans­formers
    750 VA
  • Elec­tronic trans­formers
    750 W
Meas­ure­ment
  • Exten­sion unit input
    with exten­sion unit input for BLC exten­sion unit, BLC controller exten­sion unit for motion detector and push-but­ton, NO contact
Mater­ials
  • Colour
    not applic­able
  • Material
    Plastic/­metal
Lighting control
  • - uncom­pensated
    500 VA
Fluor­es­cent bulbs control
  • Fluor­es­cent lamps in duo circuit
    1000 VA
Incan­des­cent bulbs control
  • 230 V halogen lamps (HVAC-chan­nel)
    750 W
  • 230 V incan­des­cent lamps and halogen lamps
    1000 W
Install­a­tion, mounting
  • Install­a­tion mode
    with spreader claws
Connec­tion
  • Type of connec­tion
    with screw terminals
  • Contact
    with delay time HVAC relay contact for e.g. valve drive, ther­mo­stat, fan ...
Settings
  • HVAC-channel adjustable
    ≈ 2/10/30/60/120 mn
Accessories included
  • Matching products
    insert suit­able for BLC buttons
Equip­ment
  • Switch on delay HVAC-channel
    0/3 mn
  • Poten­tial-­free
    poten­tial-­free HVAC contact suit­able for func­tion extra-low voltage FELV (only altern­ating voltage)
  • Switches / socket outlets
    also usable as push-button relay switch
Use condi­tions
  • Oper­ating temper­ature
    5…35 °C
Iden­ti­fic­a­tion
  • Applic­a­tion, usage
    Light control, Radio bus - oper­ating systems, Motion detector, HVAC control
  • Release issue
    2.1
  • Secondary design line(s)
    Light control, Motion detector, Radio bus
Instruc­tions
  • Inform­a­tion text
    For elec­tronic ballasts and energy-saving lamps with excessive switch-on currents, use switch-on current limiters order no. 185. Light scene func­tion (On/Off) in conjunc­tion with BLC radio button.